How to Write Wind Load into a Pergola Enquiry
Wind load is the requirement most often left out of a pergola enquiry, and it is the one that decides whether the structure is still there after a storm. Buyers send a bay size and a colour, and nobody writes down what the wind does at that site. The gap is not technical: it is a missing line on the request. This note explains what to write so a supplier can price the right frame and the right anchor.
What wind load actually is, in one paragraph
Wind load is a pressure, not a speed, and it is calculated from the local wind speed at the site, the height of the structure, the exposure of the ground around it and the shape of the roof. In Europe the calculation follows EN 1991-1-4 and the national annex of the country; most other markets have an equivalent code. The output is a pressure in kilonewtons per square metre, applied as suction on the roof and as pressure on the frame.
A louvered roof is worse than a flat roof in this respect: the blades form a surface that can lift, and a roof that is 4 metres high on an open site sees a different pressure from the same roof in a walled courtyard.
The five facts to put in the enquiry
- Location — the town is enough for a supplier to look up a basic wind speed; the exact site matters for exposure.
- Exposure — open coast, open field, suburban garden, dense town, or enclosed courtyard.
- Height — from ground to the top of the roof, not to the beam.
- Bay sizes and number of bays — the pressure acts on the area, and the area is the bay.
- The code the project must satisfy — EN, ASCE, AS/NZS or a local code, plus any requirement from the client’s own engineer.
Add the design life and whether the structure is temporary. A pergola for a seasonal restaurant has a different design assumption from one on a permanent terrace.
Two different questions that get confused
The first question is what the frame must resist. The second is how the frame is held to the ground. A frame can be strong enough and still fail because the base is anchored for a garden, not for the coast. Both belong in the same conversation, and the anchor set has to be chosen after the pressure is known, not before.
This is why we ask for the site photo and the exposure with the bay size: the answer changes the post section, the plate size and the anchor, and none of those can be guessed safely.
What to expect from a supplier
A serious supplier either provides a load calculation or asks a structural engineer to sign one for the specific project. A supplier who says ‘it is strong enough’ without a document is offering an opinion, and an opinion is not something a building control officer will accept. Ask for the calculation in writing, and ask which code it follows.
If the project needs a signed document, say so at the quotation stage. A calculation for a specific bay in a specific country takes time, and it is much cheaper to include it in the first quote than to commission it after the frames are cut.
Closed roof, open roof: two different cases
A blade group in the closed position presents a continuous surface to the wind, which is the case that produces uplift. In the open position the blades let air through and the load drops, though the frame still sees pressure on the posts and beams. A design that is checked only in the open position is a design checked for the wrong day: storms arrive with the roof closed because the owner closed it when the rain started.
Write the design case into the requirement — closed and secured — so the structure is assessed for the condition it will actually be in during the worst weather.
What a calculation should state
Basic wind speed for the location, terrain category, the pressure coefficient used, the resulting design pressure, the bay dimensions it applies to, and the frame sections that satisfy it. Then a separate line for the base: plate size, anchor type and the uplift each anchor is designed for. A document with the first list and no second list is half a calculation.
Where the anchor detail comes from
From the uplift figure and the substrate. A concrete slab with 200 mm thickness takes one detail; paving over a sub-base takes another; a wall plate on a single-skin wall takes a third. Send the substrate with the wind requirement and the two arrive together.
The sentence that saves a project
One line in the enquiry does most of the work: ‘Design wind pressure for this site is X kN/m2 to code Y, exposure Z, height H.’ Fill in the four blanks and the supplier can price a structure that will still be standing in ten years. Leave them out and everybody is guessing, including the person signing the drawing.
Related: wind and snow load: three numbers buyers forget.
Next step: the three series and their specifications are on the louvered pergola product page. If you already have bay sizes, send them through the contact form for a first price.
Keep reading

Sample, Trial Order and MOQ for Aluminium Structures
Sample, trial order and MOQ on aluminium structures: what a trial proves, why one set costs more per…
Read article →
City-Centre Installations: Access, Permits and Working Hours
City-centre pergola installation: access route before price, what triggers a permit, working hour limits, waste, and setting out…
Read article →
Glass Sliding Doors under a Louvered Roof
Glass sliding doors under a louvered roof: track and threshold, roof fall versus door head, glass weight and…
Read article →Related notes
- What the Installer Needs on Site Before the Crate Is Opened
- Setting Out a Bay: Square, Level and Fall in One Pass
- Anchoring a Pergola into Existing Paving Without Breaking It